• Hassi Messaoud, Algérie
  • Services
  • Plus de 1 000 personnes employés

Corrosion Monitoring Qualified Technician for Hydraulic Retriever Use

Vous ne pouvez pas postuler à une offre expirée
  • Nom de l'entrprise Red Med Groupe
  • Secteur d'activité Services
  • Lieu de travail Centre, Algérie| Est, Algérie| Ouest, Algérie| Sud est, Algérie| Sud ouest, Algérie
  • Date d'expiration 16 Février
  • Nombre de postes 02 postes ouverts
  • Niveau de poste Responsable d'équipe| Confirmé / Expérimenté
  • Niveau d'étude (diplome) Master 2, Ingéniorat, Bac + 5
  • Type de contrat CDD ou Mission

Rresponsibilities :

  • Equipment for internal corrosion monitoring is frequently used in pipe systems and vessels, especially within the oil industry. Such internal corrosion monitoring equipment can be e.g. Corrosion probes, weight loss coupons and bio probes. This type of equipment is normally installed in access fittings (of which there are many types) which have been installed on the pipe/vessel. A special version of the access fittings (T-type fittings) can also be used for installation of equipment for injection of chemicals or sampling of the contents in the pipe.
  • The Double Acting Hydraulic Retriever is a tool which is designed for servicing all kinds of equipment that can be installed into access fittings. With the Double Acting Hydraulic Retriever, equipment can be installed into or retrieved from access fittings while the pipe system is in normal operation, i.e. under full operational pressure. The standard Double Acting Hydraulic Retriever has a pressure rating of 420 bar (6.090 psi).
  • Operation of a retrieval tool on a pressurized system can be very dangerous, and must only be attempted by properly trained personnel, using procedures approved by the owners of the operating system.
  • It is very important though, that the hydraulic retriever should only be operated by people who fully understand how it works, and are trained in its use. Operators should, before working on any "live" pipe system, be sufficiently trained by qualified instructors.
  • Operators should also be familiar with the different components that are used with the Hydraulic access fittings, e.g. Hollow and Solid Plugs, Locking Pins, Hydraulic Covers and the different types of seals used on these parts.
  • Routine retrieval/replacement/installation of all existing and new locations’ monitoring elements i.e. coupons, probes, etc. standards and procedures. Coupon” shall be evaluated as per annual monitoring or hot-spot campaigns as defined Designated Corrosion Engineer.
  • Install/retrieve corrosion monitoring, Coupons when required by designated Corrosion Engineer in order to closely evaluate corrosion inhibitor efficiency and/or dosageoptimization.
  • Place the coupons post their retrieval in a plastic bag, sealed and marked as appropriate, with location, coupon number and date of retrieval.
  • The Corrosion Monitoring Engineer shall submit a program, for regular checking & maintenance of corrosion monitoring fittings, heavy duty covers including bleed valves & flanges and present a report after each corrosion monitoring campaign on their condition to designated Corrosion Engineer.
  • The Corrosion Monitoring Team must ensure that all sealing components of the corrosion monitoring assembly are checked and are in a satisfactory condition. Parts such as primary seals, O-rings, etc. m ust be replaced with new sets each time the fitting is serviced.
  • Additionally, thread tapping and seat reaming, should be used for tight fittings. - Representative samples of deposits, if present, shall be removed from coupons immediately upon their retrieval and placed in clean sealable plastic bag marked with coupons numbers, date and location. Sealable bags shall be provided by the Contractor on no cost.
  • Sealable bags to be handed-over to designated Corrosion Engineer for further handling and assessment.
  • Corrosion inhibitor (chemical injection) and analysis skills.

 

Profile :

  • Corrosion Monitoring Technician should possess/certified as Corrosion Technician, in accordance with NACE Certification Program, with at least 4 years of experience in Corrosion Monitoring.
  • He should be fully conversant with operating Corrosion Monitoring online retrieval systems (CorrOcean type, now Emerson/Roxar or EuropCorr) and maintenance of the same. He should be capable of conducting basic chemical and microbiological field tests, Rapid Check and recording and entering data into Excel Spreadsheets.
  • He should be able to use, maintain and service data logging and relevant instrumentation used for corrosion monitoring with electrical probes.

 

Vous ne pouvez pas postuler à une offre expirée
  • Nom de l'entrprise Red Med Groupe
  • Secteur d'activité Services
  • Lieu de travail Centre, Algérie| Est, Algérie| Ouest, Algérie| Sud est, Algérie| Sud ouest, Algérie
  • Date d'expiration 16 Février
  • Nombre de postes 02 postes ouverts
  • Niveau de poste Responsable d'équipe| Confirmé / Expérimenté
  • Niveau d'étude (diplome) Master 2, Ingéniorat, Bac + 5
  • Type de contrat CDD ou Mission
  • Hassi Messaoud, Algérie
  • Services
  • Plus de 1 000 personnes employés